An experimental and signal analysis workflow for detecting cold-induced noise emissions (cold squealing) from porous journal bearings
DOI:
https://doi.org/10.31224/osf.io/6yme2Keywords:
cold squealing, joint time-frequency analysis, porous journal bearings, tribologyAbstract
We employ a variant of the joint time-frequency analysis (JTFA) for identifying transient, temperature-dependent noise emitted from porous journal bearings operated at temperatures between -40°C and 0°C. This phenomenon, called "cold squealing", is difficult to reproduce in laboratory environments, as it requires a suitable (and typically system-specific) resonator to occur. We systematically tested real-world bearings impregnated with various oils on a custom-designed experimental rig, fitted with a coolable sample holder and a vibration sensor, over a range of rotational speeds. By analyzing temperature-differential JTFA signal maps, we succeeded in detecting transient cold-squealing as well as ranking the bearing lubricants according to their low-temperature quiet running properties.Downloads
Download data is not yet available.
Downloads
Posted
2018-05-02