Preprint has been published in a journal as an article
DOI of the published article https://doi.org/10.1016/j.tws.2023.111252
Preprint / Version 1

Hysteretic Energy Dissipation Capacity of Dual-Steel Welded-Plate Preloaded Bolted T-stubs

##article.authors##

  • Fangxin Hu South China University of Technology https://orcid.org/0000-0003-0822-743X
  • Tao Lin South China University of Technology
  • Zhan Wang South China University of Technology

DOI:

https://doi.org/10.31224/3051

Keywords:

Bolted T-stubs, Dual-steel, High-strength steel, Hysteretic energy, Cyclic, Welded plate

Abstract

With the high- and ultrahigh-strength steels applied in the construction industry, the seismic safety of their structural components is very concerned due to the inferior material ductility of those steels. The current studies on bolted high-strength steel T-stubs mainly focus on their monotonic loading behavior. There is limited research work conducted to study their cyclic loading behavior. In this study, cyclic tests of bolted dual-steel T-stubs were conducted. Their T-elements were produced by Q690 high-strength steel flanges and Q355 normal-strength steel webs, and class 10.9 high-strength bolts with pretension were used to connect the groove-welded T-elements. Failure modes, force-deformation hysteretic and backbone curves, cumulative plastic deformation and energy dissipation capacities were tested and analyzed. The test results indicated that an optimal β ratio between the plastic resistances of Mode 1 (neglecting the influence of bolt action on a finite contact area) and Mode 3 in Eurocode 3 Part 1-8 could be 0.3 for those bolted T-stubs to maximize hysteretic energy dissipation. Accordingly, predictive formulas with good precision were proposed for the low-cycle fatigue failure criterion and hysteretic energy dissipation capacity of those bolted T-stubs, respectively.

Downloads

Download data is not yet available.

Downloads

Posted

2023-06-12