Cross Regulation of a Leakage-Compensated Multi Output Auxiliary Power Supply
DOI:
https://doi.org/10.31224/3737Keywords:
power supply, DC-DC converter, resonant, gate driverAbstract
Transformer isolated, multi-output power supplies (MOPS) are useful as gate drivers auxiliary supply in multi switch conversion systems such as motor drive inverters. This work investigated the use of series resonant capacitors at the secondaries of the transformer to compensate the leakage inductance and explored the issues of cross regulation and parasitic oscillation at light load. Analytical, simulation and experimental studies, conducted in this work, showed that good overall performance can be obtained by the proposed choice of the components of the MOPS.
Downloads
Download data is not yet available.
Additional Files
Posted
2024-05-28
License
Copyright (c) 2024 Sam Ben-Yaakov
![Creative Commons License](http://i.creativecommons.org/l/by/4.0/88x31.png)