Preprint / Version 1

Hierarchical Bayesian inference of β-lactoglobulin denaturation and lactic acidification kinetics for a stirred-yoghurt line: a meta-analysis of published kinetics and its consequences for process design

##article.authors##

DOI:

https://doi.org/10.31224/8846

Abstract

In an earlier preprint I optimised a stirred-yoghurt line with a deterministic model, and the optimiser pushed pasteurisation to the upper bounds of temperature and holding time. That result rests on single values of the kinetic constants. Published work on β-lactoglobulin (β-Lg) denaturation in milk does not agree on those constants: reported orders run from 1 to 2, and the Arrhenius break sits anywhere between 83 and 95◦C. Here I treat the disagreement as uncertainty and follow it through to the design. The model part gives a normalised two-regime Arrhenius law with a smooth break, a rational lifting for symbolic identifiability analysis, the gradient of the stopping time at pH 4.60, and a chance-constrained version of the optimisation. The data part is a hierarchical Bayesian meta-analysis of four studies, seven entries in all. The data are of three kinds: 107 points of the Dannenberg and Kessler curves, digitised from a published re-plot; nine isothermal rate constants from Claeys et al.; and the Arrhenius regressions of Manji and Kakuda and of Oldfield. The population activation energy is 280 kJmol−1 (95% interval 261–299) below the break and 51 kJmol−1 (44–62) above it. The break lies at 89.6 ◦C (86.6–92.4), and the mean order is 1.56 (1.21–1.90). At 90◦C the rate constants of the seven entries span a factor of four. For a milk that has not been characterised, the predicted denaturation after 300 s at 90 ◦C has a 95% interval from 0.54 to 1.00. The value used in the earlier preprint, 0.80, falls at the 18th percentile. StructuralIdentifiability.jl shows that one non-isothermal curve identifies Ea/R globally. From pH data alone, the growth rate, the lag variable and the product of the buffering peak with its shape factor are locally identifiable. Uncertainty does not move the optimum away from 95◦C and 600 s. If the plant also sets a ceiling on denaturation, no operating point meets both chance constraints until the plant’s own milk has been measured. With two (simulated) measurements on that milk, a ceiling of 0.92 is met at 92.5 ◦C and 420 s. Batch variability means that four tanks sized deterministically are too small for about 62% of simulated batches.

Downloads

Download data is not yet available.

Downloads

Additional Files

Posted

2026-11-19